These skid mounted, packaged systems utilize a horizontal water bath vaporizer with a venturi type mixing system. Designed for capacities from 14MM BTU to over 250MM BTU per hour, the units are manufactured to meet or exceed requirements of the ASME Pressure Vessel Code and latest edition of NFPA Pamphlet #58. Intended for intermittent service, the units are approved for Factory Mutual (FM) or Industrial Risk Insurers (IRI) installations, and are also approved by Canadian Standards Association (CSA).

Standard design output pressure is 5 to 10 psig. Higher pressures of up to 50 psig are also available and require compressed air for operation. The vaporizer model number (WB) designates gallons per hour propane vaporization at 0 °F inlet temperature, and the mixer model number (HVS) designates millions of BTU per hour propane-air mixture. The m
odel number of the vaporizer capacity requirement determines the type of vaporizer and all burner and safety features. Electrical requirements: AC 115 V 60 Hz, single phase, or 
AC 480 V 60 Hz, 3-phase (larger units).

All module units are designed for outdoor installation and require only nominal preventive maintenance. All units are manufactured to IRI specifications, and bear Factory Mutual (FM) and Canadian Standards Association (CSA) Approval.

For detailed technical specifications of the two main modules, horizontal water bath vaporizer and Hallberg venturi mixing system, please refer to the pages for these components:

Horizontal Water Bath Vaporizers.
Venturi Type Mixing Systems for use with existing vaporizers.

AES Module Units include the following features:

  • Standard output pressures of 5 to 8 psi do not require compressed air.
  • Configurations with naturally aspirated Venturis are available for delivery pressures up to 12(15) psi.
  • Air-assisted configurations are available for delivery pressures up to 50 psi.
  • Designed to supply LP/Air Mixtures compatible with Natural Gas requirements of 14MM BTU to over 250MM BTU per hour.
  • Vaporizing and Mixing units are mounted on common skid.
  • Meet industry specifications outlined in ASME Boiler & Pressure Vessel Code, Section I, Division I, and NFPA #58.
  • Factory Mutual (FM) and Canadian Standards Association (CSA) approved.
  • Suitable for IRI Installations.
  • Controls are mounted in weatherproof cabinet.
  • System Control Panel available with UL Approval (UL 508 A).
  • Utilize a water and antifreeze solution as heat exchange medium.
  • Water Circulating Pump to provide even heat distribution in the water/antifreeze solution.
  • Electronic System Controls (PLC) with First-Outage Monitor and Digital Operator Interface.
  • Color LCD display with touch screen operator interface standard on systems with 30MMBTU/h and higher.
  • Units are factory tested, primed, painted and ready for installation and connection to liquid propane supply.

Available Options:

  • ASME "U" Stamp for vaporization tube.
  • National Board Registration.
  • UL approval for system control panel (UL 508A).
  • Naturally aspirated Venturi Systems for delivery pressures up to 12(15) psi.
  • High Pressure System for delivery pressures up to 50 psig (requires compressed air).
  • Enlarged vaporizer control room or separate mixer and control room building.
  • Remote Monitoring and Control via dial-up modem, Ethernet interface, or Wireless
  • Integration into existing Plant Control Systems (SCADA)

WB-Vaporizer/HVS-Mixer Configurations for Standard Propane Applications.
Configurations for other LPG mixtures may vary.
Other Vaporizer/Mixer combinations are available; contact your distributor or the factory for details.

Model Number Nominal Capacity Number
Venturis
Surge Tank Capacity
Vaporizer Mixer MMBTU kcal US-gal
WB -   200 HVS -   14 MM 14 3530 2 120 0.45
WB -   250 HVS -   20 MM 20 5040 2 120 0.45
WB -   350 HVS -   30 MM 30 7560 3 250 0.95
WB -   450 HVS -   40 MM 40 10080 4 250 0.95
WB -   550 HVS -   50 MM 50 12600 5 250 0.95
WB -   750 HVS -   60 MM 60 15120 6 500 1.9
WB -   850 HVS -   70 MM 70 17640 7 500 1.9
WB - 1000 HVS -   90 MM 90 22680 9 500 1.9
WB - 1200 HVS - 100 MM 100 25200 10 1000 3.8
WB - 1500 HVS - 110 MM 110 27720 11 1000 3.8
WB - 1500 HVS - 120 MM 120 30240 12 1000 3.8
WB - 1800 HVS - 130 MM 130 32760 13 2000 7.6
WB - 1800 HVS - 140 MM 140 35280 14 2000 7.6
WB - 1800 HVS - 150 MM 150 37800 15 2000 7.6
WB - 1800 HVS - 160 MM 160 40320 18 2000 7.6
WB - 2000 HVS - 170 MM 170 42840 18 2000 7.6
WB - 2000 HVS - 180 MM 180 45360 18 2000 7.6
WB - 2200 HVS - 190 MM 190 47880 19 2000 7.6
WB - 2200 HVS - 200 MM 200 50400 20 2000 7.6
WB - 2500 HVS - 210 MM 210 52920 21 3000 11.4
WB - 2500 HVS - 220 MM 220 55440 22 3000 11.4
WB - 2500 HVS - 230 MM 230 57960 23 3000 11.4
WB - 3000 HVS - 240 MM 240 60480 24 3000 11.4
WB - 3000 HVS - 250 MM 250 63000 25 3000 11.4
For detailed System Specifications, follow these links:
WB-Series Vaporizers:     Web Page       Download Datasheet (PDF File)
HVS-Series Mixers:           Web Page       Download Datasheet (PDF File)
WB/HVS Packaged Systems:                   Download Datasheet (PDF File)
 
 
 
 
 

HOME | PRODUCTS | VAPORIZERS | MIXERS/BLENDERS | PACKAGED SYSTEMS | ACCESSORIES | PRODUCT APPROVALS | PRICE LISTS
DOWNLOADS | TECHNOLOGY | LPG PROPERTIES | SYSTEM SIZING WORKSHEET | NEWS | AES COMPANY PROFILE | AES LOCATION
AES CONTACTS | LITERATURE REQUEST | SEARCH | SITE MAP GraviBlend-3 GRAVITOMETER OTHER BLENDING APPLICATIONS