| Type |
Equal Pressure Blending System
print window
POM - 100 Piston Operated Gas / Air Mixer |
Nominal
Capacity
LP/Air Mix with 1500 BTU/cuft
LP/Air Mix with 13000 kcal/m³ |
300
MMBTU/h
@ 10 psig to over 2000 MMBTU/h @ 100 psig
75 MMkcal/h @ 1 bar to over 500 MMkcal/h @ 7 bar
200,000 scfh @ 10 psi to over 14,000,000 scfh @ 100 psi
5700 Nm³/h @1 bar to over 38000 Nm³/h @ 7bar |
| Design Temperature |
180 °F
/ 80 °C |
| Air
Supply |
Clean, Dry Compressed Air |
| Manufactured Construction |
Conforms to ASME Boiler & Pressure Vessel Code
Conforms to latest edition of NFPA #58
European PED, ATEX, ..... |
| Approvals |
Factory Mutual (FM) or Industrial Risk Insurers (IRI)
CE Mark for European Versions |
| Standard Safety Features |
- Low Vapor Supply Pressure
- High Vapor Supply Pressure
- Low Air Supply Pressure
- High Air Supply Pressure
- Low Mixed Gas Pressure
- High Mixed Gas Pressure
- Excess Differential Pressure between Gas &
Air
- Pneumatically actuated safety
valves in air supply and vapor supply lines
|
|
System Controls |
- Allen-Bradley (or Siemens)
PLC with color-LCD Display and Touch-Screen Operator Interface
- Local Trend Recording
- Alarm History and Alarm Count
- Rosemount Pressure
Transmitters
- Explosion Proof Junction Box
Standard
- Explosion Proof Panel Optional
|
| Vapor Supply Connection |
4" Raised Face Flange
/ DN100 |
| Air Supply Connection |
4" Raised Face Flange
/ DN100 |
| Mixed Gas Outlet Connection |
10" Raised Face Flange
/ DN250 |
| Electrical Requirement |
AC
120 V 60 Hz, Single Phase, 5 Amp.
AC 220/240 V 50 Hz, Single Phase, 5 Amp. |
| Dimensions
(approximate) |
180" x 72" x 80" (L x W x H)
4.57 m x 1.83 m x 2.03 m |
| Dry Weight
(approximate) |
2000 lbs.
900 kg |
|
Available Options |
- System Integration with LP Vaporizers
-
Automatic Gas Properties Control (Wobbe Index, O2
content, Calorific Value, or Specific Gravity)
-
Flow Control System for Peak Shaving
-
Remote Monitoring and Control via Modem, Ethernet, or
Wireless
-
Installation in Mobile Buildings
-
Integration into existing Plant Control Systems (SCADA)
-
High-Pressure Configuration up to 300 psi / 20 bar
|
| Catalog Drawing |
click here to see
catalog drawing |